Protection & an early detection against fire accidents is ensured with a range of 3 versatile models of highly feature loaded MICROPROCESSOR based fire alarm panels developed on EMBEDDED DESIGN TECHNOLOGY engineered specially for the Indian Market compliance IS 2189 STANDARD. RAVEL microprocessor based fire control Panels starting with a basic 2 zone, 4 zone (with & without LCD Display), also Upgradeable & Expandable to any number of zones.
2 ZONE FIRE ALARM PANEL- RE-120
Compatible to all types of conventional detectors
Hooter loop monitoring facility
Twin RED LED indication for fire
Zone Disable (Isolation) facility with loop voltage cutoff
Relay output for actuators
Resettable 24V DC output for4wire detectors (Optional)
Battery backup with built in charging
4 / 6 / 8 ZONE LED FIRE ALARM PANEL - RE-150
Confirms IS 2189 norms
Lamp Test facility, One man Walk Test facility
Compatible to all types of conventional detectors
Zone Isolation
RS 485 for repeater
Fire / Fault status in unambiguous colored LED indication
Standby battery back up with built in charging
Rugged CRCA sheet with powder coated finish
4 to 128 ZONE LCD FIRE ALARM PANEL - RE-700
Panel starts from 4 Zone to 128 Zone
20 X 4 LCD Dot Matrix display
Low battery/warning audio/visual display
Zone Isolation
RS 485 for Repeater / Network
Relay output for actuators
Battery fail warning audio, A.C fail audio / visual warning
Fire / fault status in unambiguous colored LED indication
Battery backup with built in charging
4 / 8 ZONE FIRE ALARM PANEL - RE-2504/08
Fully complies with UL-864 9th Edition and NFPA-72
4/8 Class B conventional initiating device circuit (IDC)
2 Class B Notification Appliance Circuits (NAC)
All field wiring circuits are supervised
Alarm verification, Programmable Trouble reminder
Events history with RTC
Zone Isolation with loop voltage cut off
Ground fault annunciation facility at 0 ohms
4 / 8 ZONE FIRE ALARM PANEL - RE-1504/08 Fully Complies with UL-864 9th edition & NFPA-72
Networkable / Standalone panel
4/8 Class B conventional initiating device circuit (IDC)
Class B Notification Appliance Circuits (NAC)
Programmable NAC, Programmable IDCs, Programmable
AC loss delay, Programmable Trouble reminder
Conventional Panel with Addressing Features
32 Detectors per zone
Individual detector address with location
Detector maintenance Low / High alert
2 ZONE WITH GAS RELEASE PANEL - RE-120 GR
16 X 2 LCD Dot Matrix Display
Evacuate and Key pad Enable, Disable Facility
Events log with RTC
Compatible to all types of conventional detectors
Resettable 24V DC output for 4 wire detectors (Optional)
Three 24V Hooter Output (Fire, Cross zone, gas release)
Two mode operation facility (Auto / Manual)
Programmable FAP input selection Facility
Programmable Solenoid Output with On and OFF Timer
Main / Standby Cylinder output Facility (Optional)